--- title: "Response file" slug: "profiles--entry-tab-6-file" updated: 2026-10-14T13:45:36Z published: 2026-10-14T13:45:36Z canonical: "docs.lobstersoftware.com/profiles--entry-tab-6-file" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.lobstersoftware.com/llms.txt > Use this file to discover all available pages before exploring further. # Response file ## Settings ![images/download/attachments/201684249/7-version-1-modificationdate-1749440593184-api-v2.png](https://cdn.document360.io/4be90b94-ec83-41d8-963e-962df16110d4/Images/Documentation/7-version-1-modificationdate-1749440593184-api-v2.png) (1) **Is backup of target data:** This checkbox creates backup output files that are assigned to the job and can be viewed in the Control Center on page "Overview". This gives you a chance to check which data has been sent. If several responses have this option set, only the content of the last one is available. A name of the output file cannot be specified. The output file is created in the backup directory of the Profile and has the name `ARC_<job number>_<Response number>`. If the option "Enter output channels for each record" is set (see [Extended (Phase 2)](/v1/docs/en/profiles--tab-3-advanced)), the output files have the name `ARC_<job number>_<record number>#<Response number>`. (2) **Channel selection:** You can select an "SMB" channel here. See also (3) and (4). **IMPORTANT:** The complete UNC path (see [File names, file patterns, paths, placeholders](/v1/docs/en/intro-concepts-files-names-patterns)) to the file (3) must be specified, since the server specification in the channel only serves for the log in. > [!NOTE] > **NOTE:** > > If an SMB channel is selected, the value `//<SMBHOST>/` is automatically entered in (3). The placeholder `<SMBHOST>` is replaced at runtime with the value of field "Server*"* in the SMB channel (without `smb://` ). Old profiles (which do not yet contain the placeholder) can be adjusted in the Admin console by [Class execution](/v1/docs/en/ac-environment-classexec) `com.ebd.hub.datawizard.util.update.AdjustSMBUrl` (without parameters). (3) **File:** Path and file name pattern of the output file. Under Windows, [External shares](/v1/docs/en/intro-external-systems-external-shares) access is possible using the UNC syntax: `//<server name>/<directory name>`. Slashes (`/`) and no backslashes (`\`) are to be used. (4) **SMB share:** When accessing external shares, you can specify an explicit SMB login or use a channel (2). (5) **Append:** If this checkbox is set, no new file will be created for the output data, instead, it will be added to the end of an already existing file. But if the file does not exist yet, it will be created. Attaching to an existing file is not possible in the following cases. In those cases, the setting of the checkbox will be ignored and a new file will always be created. - Output format XML. An XML file may only have one root node. - Output format Excel. An Excel file is a file in a binary file format. - A file containing compressed data is also a file in a binary file format. (6) **Target directory must exist:** If this checkbox is set, there will be a check to see if the destination directory exists before writing the file. If it does not exist, the response creates an error. This checkbox should be used especially if the destination directory is a mounted directory. (7) **Transmit empty data:** If this checkbox is set, empty files are transferred as well. (8) **Mark whole job as failed if this response fails:** Normally a job is not necessarily considered to be erroneous if a single response fails (see [Dependencies](/v1/docs/en/phase-6-response-dependencies)). But it can be enforced with this option here. (9) **Additional text on error:** Here you can specify an additional log text for the error case. > [!NOTE] > **NOTE:** > > - See also [Functions (GUI)](/v1/docs/en/phase-3-target-structure-functions). > - If the content to be written to a file is empty, the response is not entered. That is, no output file is generated. This behavior can be changed by setting the system property `-Ddatawizard.removeZeroFile=false`. If this property has the value `false` and the content is empty, the response is entered and a file is created, or the empty content is attached to an existing file. Central operational overview of the Lobster Data Platform. The Control Center displays running jobs, successful jobs, and error logs. Administrators use it to monitor operations, intervene in running jobs, and restart failed jobs. A profile is the central configuration unit in the Lobster Data Platform. It receives data, processes it, and forwards it. Configuration is done graphically, with no programming required. A central data record in partner management that consolidates the connection parameters for a communication partner, such as the URL, access credentials, and protocol. Changes to a channel immediately affect all profiles, ASM entries, and content inspection entries that use that channel. The Integration Server's user interface for configuration, operation, and diagnostics. The Admin console manages services, users, passwords, databases, and system settings. It is independent of the Control Center and is intended for system administrators. XML (Extensible Markup Language) is a structured text format for storing and exchanging data. Content is enclosed within freely definable tags such as `<order>`. XML is human-readable, machine-processable, and platform-independent. In the Lobster Data Platform, you can receive, parse, and generate XML data.